ASSEMBLING THE OVEN TO THE STAND
Unpack the oven and stand. Position oven on its back, taking care not to scratch or damage it. The gas pipe
connection protrudes beyond the back; provide for this when the oven is tipped back by resting it on suitable
spacers (2 x 4's etc.).
Install the two locating studs (included in the stand carton) into the screw plates on the underside of the oven
(see Fig. 3).
Attach each of the four leg assemblies to the bottom of the stand with the 24 bolts and lockwashers (6 per leg).
Mount the oven on top of the stand.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE
PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT
SWITCH TO INDICATE THAT YOU ARE WORKING ON THE CIRCUIT.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE PROVIDED WITH
A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE CONNECTED INTO A
PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER
GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM
THIS PLUG.
The 120 volt models have a cord and plug attached and do not have to be wired.
When installed, the appliance must be electrically grounded in accordance with local codes, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA No. 70 (latest edition).
Refer to electrical wiring diagram located inside the right side panel; remove control panel for access.
Do not turn the power supply on until after the gas connections have been made and checked for leaks.
GAS AND ELECTRICAL DATA
GAS DATA ELECTRICAL DATA
INPUT BTU/HR MANIFOLD PRESSURE Load AMP/LINE
Natural Propane Natural Propane (Watts) 120 V
Single Oven 25000 25000 3.5" w.c. (0.8 kPa) 10" w.c. (2.5 kPa) 950 8
Stacked Ovens 50000 50000 3.5" w.c. (0.8 kPa) 10" w.c. (2.5 kPa) 1900 16
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.
The oven is provided with a regulator integral to the gas solenoid valve, and requires no regulator external to
the device.